Wuhan Bonnin Technology Ltd, Laboratory Instruments Expert in China

Product Description

The K5600 K5600C micro-spectrophotometer, a new type full-spectrum(200~850nm) spectrophotometer, can measure nucleic acids, proteins, cell cultures, micro array samples, and UV-VIS full spectrum absorbance scan with high accuracy and reproducibility. Adding dark room for cuvette, you can choose cuvette or test platform.

Features

0.3~2µL sample size!

Cuvette or test platform!

No warm-up!

Rapid measure speed!

Display the concentration directly!

UV-VIS full spectrum absorbance analysis (200-850nm)!

No dilutions for samples, can measure samples with high concentration!

Easy to use!

Technical data

Path length: 1mm, 0.2mm, (0.1mm, 0.05mm optional)

Sample size: 0.3~2µL

Light source: Xenon flash lamp

Detector: 2048-element linear silicon CCD

Wavelength range: 200~850nm

Cuvette size(path length): 1mm, 2mm, 5mm, 10mm

Wavelength accuracy: ±1nm

Wavelength resolution: 2nm (FWHM at Hg 546nm)

Absorbance precision: 0.002 Abs

Absorbance accuracy: 1% (0.76 absorbance at 350nm)

Absorbance range: 0.002~75(150, 300 optional, 10mm equivalent absorbance)

Detects Nucleic acid up to: 0.4~3750ng/μL(7500,15000 optional, dsDNA)

Detects Protein up to: 0.01mg/ml~100mg/ml(200,400 optional, BSA)

Measurement time: <5s

Outline size: 24cm×21cm×11cm

Net weight: 1.92kg

Application

There are 5 measurement modules provided by K5600 software: Nucleic acid, Protein, Cell culture, Microarray and UV-VIS.

Nucleic Acid: Concentration and purity of DS-DNA, SS-DNA and RNA

Protein: Concentration of the protein A280(1Abs = 1mg/mL), BSA, IgG and lysozyme

Concentration of protein with protein assay kit (Lowry, BCA and Bradford)

Cell Culture:Concentration of suspended cell cultures

UV-VIS: UV/VIS full-spectrum (200~850nm) absorbance scan

Microarray:Concentration of fluorescent dye labeled nucleic acid (microarray), for it can measure the concentration of the nucleic acid and the dye at the same time

General operation

1 Drop directly 0.3~2µL sample onto the test platform with a pipette.

2 Close the sampling arm.

3 Or open the dark room and put the cuvette into it.

4 Click the “Measure” button, and the result(values and graph) of the sample will appear in seconds.

5 Wipe the sample from the test platform with clear absorbent paper.

6 Click the “Save Graphic” button after measured a sample if you want to save the graph.

7 Click the “Show Report” button after the samples measured to output the result data of the samples by excel.

K5600C cuvette parameters
Trial cuvette specifications (light path): 1/2/5/10mm
Cuvette minimum volume: 50μl
Sample level height: 5mm
Type: Recyclable micro cuvette
Cuvette darkroom: standard cuvette darkroom, suitable for multi-size cuvettes

Enquiry For K5600/K5600C Micro Spectrophotometer