BZY100 & BZY200 surface tensiometers used to test the surface and interfacial tension of liquid samples, use two measurement methods and built-in data memory, so they can be used independently to meet the needs of various purposes.
BZY100 & BZY200 surface tensiometers used to test the surface and interfacial tension of liquid samples, use two measurement methods and built-in data memory, so they can be used independently to meet the needs of various purposes. The instrument is lightweight, easy to install, and can be moved quickly.
Applications:
Related standards:
Satisfies partially valid norms and standards
ASTM D971 Standard Test Method for Oil-Water Interfacial Tension Using the Lifting Ring Method
ASTM D1331 Standard Test Method for Surface and Interfacial Tension of Surfactant Solutions
ASTM D1417 Standard Method for Testing Synthetic Rubber Latex
DIN EN 14210 Surfactants – Determination of the interfacial tension of surfactant solutions by the stirrup or ring method
DIN EN 14370 Surfactants – Determination of surface tension
ISO 304 Surfactants – Determination of Surface Tension by the Pull Film Method
ISO 1409 Plastics/rubber – Polymer dispersions and rubber latexes (natural and synthetic) – Determination of surface tension by the ring method
ISO 4311 Anionic and nonionic surfactants — Determination of critical micelle concentration — Determination with hangers, stirrup rings or rings
surface tension method
OECD 115 OECD Guidelines for Testing Chemicals: Surface Tension of Aqueous Solutions
ISO 6889 Surfactants – Determination of surface tension by the pull film method
Features:
▇Using a 4.3-inch touch screen, all operations and information are completed or displayed on the screen.
▇ It can be used to measure the surface interfacial tension of liquids.
▇ Simple and fast operation.
▇ Automatic measurement with high repeatability can be achieved for the set measurement conditions.
Technical Parameters:
Model | BZY100 | BZY200 |
Test Method* | Du Nouy Ring Method & Wilhelmy Plate Method | |
Test Range | 0-1000mN/m | 0-1000mN/m |
Resolution | 0.1mN/m | 0.01mN/m |
Operation Method | Automatic lifting and lowering of sample stage
|
|
Display Method | 4.3-inch touch screen data direct reading | |
Data Method | Support data storage/view/print | |
Measure Time | Normally within 60 seconds | |
Data Output** | RS232(Printer) | |
Dimensions | 28*20*36cm(L*W*H) | |
Net Weight | 8kg | |
Power Supply | AC110V or 220V、30W |
Ring size: Pt wire radius is 0.185mm, ring radius is 9.55mm, ring circumference is 60mm.
*Note: The plate/ring test method needs to be specified when ordering. The standard configuration is to choose one from the other.
If the budget is sufficient, it is recommended to configure both the plate and the ring.
**Note: The printer is not included in the standard configuration, please purchase it as required.