HPC501 Automobile exhaust gas analyzer is used to measure the concentration of HC, CO, CO2, O2 and NOx in the exhaust gas of automobiles, automatically calculate and display the air-fuel ratio λ, and can comprehensively detect engine combustion performance and emission pollution. Adopting foreign advanced technology and imported German movement. It has high-brightness digital display, automatic zero calibration, automatic data linearization processing, automatic alarm when the gas path is blocked, and automatic diagnosis of the unit when the fault occurs. The instrument is suitable for the detection of engine exhaust components of gasoline, LPG, CNG, alcohol and diesel fuel. , Optional built-in printer (or Bluetooth, RS232, analog interface), meet the new national standard GB18285-2018 and the US BAR-97 standard, meet ISO3930 or OIMLR99 class I accuracy, can perform free idle speed, double idle speed measurement and multi-condition measurement, It has the characteristics of convenient operation, accurate measurement data, stable and reliable work.

 

Main technical parameters:

Measuring range   HC: 0~10000×10-6(ppm)vol CO: 0~14×10-2(%)vol

CO2:0~20×10-2(%)vol O2: 0~25×10-2(%)vol

NOx:0~5000×10-6(ppm)vol λ:0.50~3.00 COcor:0~10×10-2(%)vol

Indication error  HC ± 12 × 10-6 (ppm) vol (absolute error) or ±5% (relative error)

CO±0.06×10-2(%)vol (absolute error) or ±5% (relative error)

CO2 ±0.5×10-2(%)vol (absolute error) or ±5% (relative error)

O2 ±0.1 ×10-2(%)vol (absolute error) or ±5% (relative error)

NOx ±25 ×10-6 (ppm) vol (absolute error) or ±4% (relative error)

Note:  The absolute error and relative error listed above can meet one of the requirements.

Repeatability  Repeat error≤±2%

Stability  Automatic zero calibration, torque drift ≤±3%

Resolution  HC: 1×10-6(ppm)vol CO: 0.01×10-2(%)vol CO2: 0.1×10-2(%)vol

O2: 0.01×10-2(%)vol NOx: 1×10-6(ppm)vol λ:0.01

Response time  95% response is not more than 10 seconds

Warm-up time  8min (3min can be preheated for emergency detection)

Output mode  Digital direct reading display, printer can be attached to print the gas name, maximum concentration, test time, day

Period and so on. Can attach interface and computer network

Environmental conditions   Temperature -5~50℃, relative humidity ≤90%

Power supply  AC100-240V 50/60Hz or DC12V (optional power inverter) power consumption 40VA

Dimensions  420mm (length) × 310mm (width) × 170mm (height)

Weight  about 9kg